https://doi.org/10.1016/j.nima.2019.162967 ·
Full text
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020, p.162967
Publisher: Elsevier BV
Authors:
- Mohit Gola
- Shivali Malhotra
- Aashaq Shah
- Asar Ahmed
- Ashok Kumar
- Md. Naimuddin
Funders
List of references
- Sauli, GEM: A new concept for electron amplification in gas detectors, Nucl. Instrum. Methods A, № 386, с. 531
https://doi.org/10.1016/S0168-9002(96)01172-2
- Sauli, Gas detectors: Recent developments and future perspectives, Nucl. Instrum. Methods A, № 419, с. 189
https://doi.org/10.1016/S0168-9002(98)00793-1
- Sauli, The gas electron multiplier (GEM): Operating principles and applications, Nucl. Instrum. Methods A, № 805, с. 2
https://doi.org/10.1016/j.nima.2015.07.060
- Bucciantonio, Proton computed tomography, Mod. Phys. Lett. A, № 30
https://doi.org/10.1142/S0217732315400246
- Naimuddin, Development of a proton computed tomography detector system, J. Instrum., № 11, с. C02012
https://doi.org/10.1088/1748-0221/11/02/C02012
- Wang, Nucl. Instrum. Methods A, № 701, с. 54
https://doi.org/10.1016/j.nima.2012.10.078
- Alon, Time resolution of a thick gas electron multiplier (THGEM) - based detector, J. Instrum., с. P11001
https://doi.org/10.1088/1748-0221/3/11/P11001
- Bachmann, Nucl. Instrum. Methods A, № 478, с. 104108
https://doi.org/10.1016/S0168-9002(01)01719-3
- YuLian. Zhang, et al. Investigation of a hybrid structure gaseous detector for ion backflow suppression, arXiv:1609.08010v3.
- Gnanvo, Nucl. Instrum. Methods A, № 782, с. 77
https://doi.org/10.1016/j.nima.2015.02.017
- CMS Collaboration, CMS Technical Design Report for the Muon Endcap GEM Upgrade, CMS-TDR-013, 2015.
- Villa, Progress on large area GEMs, Nucl. Instrum. Methods A, № 628, с. 182
https://doi.org/10.1016/j.nima.2010.06.312
- M. Hoch, GEM - A novel gaseous particle detector, CERN-THESIS-2005-037.
- Shah, Development, characterization and qualification of first gem foils produced in india, Nucl. Instrum. Methods A, № 892, с. 10
https://doi.org/10.1016/j.nima.2018.02.078
- Cruz, Assembly, functionality and performance of a triple gem chamber prototype, Nucl. Part. Phys. Proc., № 267, с. 427
https://doi.org/10.1016/j.nuclphysbps.2015.10.142
- Saviano, Properties of potential eco-friendly gas replacements for particle detectors in high energy physics, JINST, № 13, с. P03012
https://doi.org/10.1088/1748-0221/13/03/P03012
- Buzulutskov, GEM Operation in pure noble gases and the avalanche confinement, Nucl. Instrum. Methods A, № 433, с. 471
https://doi.org/10.1016/S0168-9002(99)00295-8
- Ahin, High-precision gas gain and energy transfer measurements in ar/co2 mixtures, Nucl. Instrum. Methods A, № 768, с. 104
https://doi.org/10.1016/j.nima.2014.09.061
- Marinov, с. 84
- The CMS experiment at the CERN LHC, JINST, № 3, с. S08004
- Bachmann, Charge amplification and transfer processes in the gas electron multiplier, Nucl. Instrum. Methods A, № 438, с. 376
https://doi.org/10.1016/S0168-9002(99)00820-7
- Bachmann, Discharge mechanisms and their prevention in the gas electron multiplier (GEM), Nucl. Instrum. Methods A, № 479, с. 294
https://doi.org/10.1016/S0168-9002(01)00931-7
- Keithley Instruments Inc. Model 6517B Electrometer Reference Manual, 6517B-901-01 Rev. B, Cleveland, (2009).
- S. Malhotra, et al. Various studies with gas electron multiplier (GEM) detectors, in: XXII DAE High Energy Physics Symposium, Springer Proceedings in Physics, p. 203. http://dx.doi.org/10.1007/978-3-319-73171-1_22.
https://doi.org/10.1007/978-3-319-73171-1_22
- M. Gola, Muon chamber endcap upgrade of the CMS experiment with gas electron multiplier (GEM) detectors and their performance, in: XXII DAE High Energy Physics Symposium, Springer Proceedings in Physics 203. doi: 10.1007/978-3-319-73171-1_139.
https://doi.org/10.1007/978-3-319-73171-1_139
- M.V. Nemallapudi, Gain of a Single Gas Electron Multiplier, (Theses and Dissertations), p. 533, 2012, http://scholarworks.uark.edu/etd/533.
- T. Maerschalk, Study of Triple-GEM Detector for the Upgrade of the CMS Muon Spectrometer At LHC (Ph.D. thesis) Universite Libre de Bruxelles, 2016.
- Ha, Energy resolution of a single GEM detector, J. Korean Phys. Soc., № 55, с. 2366
https://doi.org/10.3938/jkps.55.2366
- J.A. Merlin, Study of Long-Term Sustained Operation of Gaseous Detectors for the High Rate Environment in CMS, CERN-THESIS-2016-041 (Ph.D. thesis), (Chapter 8), p. 188, 2016.
- Bouianov, Foil geometry effects on GEM characteristics, Nucl. Instrum. Methods A, № 458, с. 698
https://doi.org/10.1016/S0168-9002(00)00897-4
Publications that cite this publication
The qualification of GEM detector and its application to imaging
A. Ahmed, A. Kumar, Md. Naimuddin, M. Babij, P. Bielowka
https://doi.org/10.1088/1748-0221/17/04/p04002 ·
2022, Journal of Instrumentation, №04, p.P04002
Scopus
WoS
Crossref citations:0
Charging-up effect and uniformity study of a single mask triple GEM detector
S. Chatterjee, A. Sen, S. Das, S. Biswas
https://doi.org/10.1016/j.nima.2023.168110
2023, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, p.168110
Scopus
WoS
Crossref citations:0
Fabrication and Characterization of Gaseous Detector for the identification of High Energy Particles.
J. Babbar, S. Bansal, S.B. Beri, V. Bhatnagar, S. Chauhan, R. Gupta, A. Kaur, H. Kaur, S. Kumar, P. Kumari, M. Meena, J.B. Singh, A.K. Virdi
https://doi.org/10.1088/1757-899x/1033/1/012055
2021, IOP Conference Series: Materials Science and Engineering, №1, p.012055
Scopus
Crossref citations:0
Find all citations of the publication
About this publication
Number of citations | 1 |
Number of works in the list of references | 30 |
Journal indexed in Scopus | Yes |
Journal indexed in Web of Science | Yes |